How to choose a power station without overpaying

Most mistakes when buying a station come down to too little capacity, so it runs out before the outage ends, or too little power, so it shuts off the moment the fridge or pump starts. It also happens the other way round: people overpay for headroom they will never use.

Below is how to work out the right station yourself in 10 minutes: what matters, what you can ignore and which models fit typical situations.

Whhow long your devices will run
Wwhat you can run at the same time
× 0.85real output after losses
LiFePO4the battery type to look for

Start with three questions

The answers decide both the model and the budget. Without them, comparing stations by specs is pointless.

What do you need to power?

List the devices that must keep working during an outage: router, laptop, lights, fridge, boiler, pump. Note the kettle and microwave separately - they run briefly but need a lot of power.

For how many hours?

For a city apartment people usually plan for 4-8 hours. For a house outside the city or regions with long outages, plan for a day or more.

Where will the station be?

If you'll take it on trips or to the country house, weight and size matter. If it will stay at home as backup, capacity, power and expandability matter more.

Capacity vs power

These are two different specs, and mixing them up is the most common reason for a bad purchase.

Capacity, Wh

How much energy the battery stores. It decides how long your devices will run. In theory, a 2400 Wh station can power a 100 W device for 24 hours.

Power, W

How many devices you can run at once. If their total power exceeds the station's power, it shuts off. Also check peak power: a fridge or pump draws 3-5 times more at start-up than while running.

How to estimate runtime: capacity × 0.85 ÷ device power. For example, 2400 Wh × 0.85 ÷ 100 W ≈ 20 hours. The 0.85 factor accounts for inverter losses - in practice a station delivers about 85% of its rated capacity.

How much power devices use

Typical values for household appliances. Check the label or manual of your own devices for exact figures.

Device Running At start-up
Wi-Fi router + fiber terminal 15-20 W -
Laptop 50-90 W -
LED lighting (several bulbs) 10-30 W -
TV 80-150 W -
Fridge 100-150 W, but runs ~40% of the time up to 600 W
Gas boiler + circulation pump 100-200 W up to 300 W
Water pump station 800-1000 W up to 2700 W
Microwave 1200-1500 W -
Electric kettle 1800-2200 W -
Washing machine up to 2200 W when heating -
Fridges and boilers run in cycles. A fridge compressor switches on and off, so in an hour it uses about 50 Wh, not 120. Use average consumption to estimate runtime and start-up power to choose the station's power.

Which station to choose: typical situations

Runtimes are estimated with the formula above and are approximate - they depend on your actual devices and how often they switch on.

≈ 90 W

Internet and working from home

Router, fiber terminal, laptop and lights. The simplest apartment scenario.

Sorein P1200 - about 10 hours. Sorein G2400 - about 22 hours, with room for a fridge.
≈ 150 W on average

Apartment with a fridge

Everything above plus a fridge and the TV in the evening.

Sorein G2400 - 13-14 hours. Sorein G4800 - about a day.
≈ 240 W on average

House with a gas boiler

Boiler with circulation pump, fridge, internet, lights and cameras. The boiler needs a pure sine wave and fast switchover when power goes out.

Sorein G4800 - about 17 hours. Sorein G7200 - about 25 hours.
peaks of 3-5 kW

House with a kitchen and pump

The same plus a kettle, microwave or induction hob and a water pump. Power is what matters here, so several heavy appliances don't trip the station.

Sorein G7200 Pro with 7200 W or G9600 Ultra with 10,800 W.
50-300 W

Country house, travel, camping

Phones, laptop, lights, a car fridge, sometimes a hot plate. You'll carry the station, so every kilogram counts.

Sorein P600 for light tasks, P2400 Pro if you need a kettle or hot plate.
≈ 300-500 W

Office or shop

Several computers, router, cash register, lights. Devices must not reboot during switchover.

Sorein G4800 covers a working day of up to 8-10 hours, then add extra batteries.

Portable or modular

Both are a battery with an inverter, but they solve different problems.

  Portable (P series) Modular (G series)
Capacity 481-2300 Wh from 2400 Wh, up to 55.2 kWh
Power 600-2400 W 3600 W per inverter, up to 18 kW
Format Compact, easy to carry On wheels, batteries and inverters added as modules
Best for Apartments, country houses, travel Houses, boilers, kitchens, offices

If you need a station at home and aren't sure the capacity will be enough, a modular system takes that question off the table: start with the G2400 and add an Extra 2400 Wh battery when you need more. All models are in the G series and P series catalogs.

What else to check

These specs are rarely printed in big letters, but they decide how the station behaves in real life.

Battery type

LiFePO4 (LFP) lasts many times more cycles than regular lithium-ion and is safer. For example, the G series is rated for 4000 cycles to 80% capacity - over 10 years of daily use.

Pure sine wave

A must for gas boilers, pumps, fridges and anything with a motor. On a modified sine wave they can hum, overheat or fail to start.

UPS mode

The station stays plugged into the grid and switches to battery when power goes out. For boilers and computers the switchover time matters - the shorter the better. On the G2400 it's under 20 ms.

Charging speed

If power comes back for only a few hours, the station must recharge in time. The G2400 charges from the grid in about 1.9 hours.

Solar panels

A solar input lets you charge without the grid and save on electricity. Check the maximum input power - up to 1000 W on the G2400. Panels in the catalog.

Sockets and ports

Count how many devices you'll connect at once. Several regular sockets plus USB-C for the laptop and phones are convenient.

Common mistakes

Looking only at capacity. A 5000 Wh station with a 1000 W inverter won't run a kettle or water pump, however much energy it stores.
Calculating with rated capacity. Inverter losses mean a station delivers about 85% of its capacity. Factor that in from the start.
Forgetting start-up surges. A fridge, pump or air conditioner draws several times more at start-up. Without enough peak power the station shuts off at exactly that moment.
Buying with no margin. Leave 20-30% headroom in both capacity and power - you'll add devices over time, and outages often last longer than the schedules say.
Ignoring charging. If power is back for 2-3 hours, a station that takes 8 hours to charge won't refill before the next outage.

Don't want to calculate by hand?

Pick your devices in the calculator - it works out the capacity and power you need and suggests a station. Or call us and we'll choose a model together.